Warning: Verify power on pins 1 and 3.
|
Machine not equipped with variable rate drive.
|
If machine is not equipped with VRD, change drive source. (See CONFIGURE PLANTER DRIVE SOURCE in SETUP Basic Planter Configuration section.)
|
|
|
Machine is equipped with variable rate drive.
|
Check pins 1 and 3 for 12 volt power at ISO coupler.
|
|
No vacuum reading.
|
Faulty wire connection.
|
Check wiring harness and repair.
|
|
|
Blower not running.
|
Start blower motor.
|
|
|
Vacuum line on wrong fitting on sensor.
|
Install vacuum line to sensor P2 fitting.
|
|
|
Incorrect planter configuration.
|
Enter correct number of vacuum sensors. (See VACUUM SENSORS in SETUP Basic Planter Configuration section.)
|
|
|
Vacuum section not displayed on RUN screen.
|
Enter correct number of vacuum sensors. (See VACUUM SENSORS in SETUP Basic Planter Configuration section.)
|
|
|
Sensor connected to wrong wire harness lead.
|
If only one vacuum sensor is used, correct to wire labeled LEFT VACUUM.
|
|
Wrong vacuum reading.
|
Vacuum sensor not calibrated.
|
Stop blower motor and zero the sensor. (See VACUUM SENSORS in SETUP Basic Planter Configuration section.)
|
|
|
Wrong calibration value.
|
Enter correct calibration value (5.66). (See VACUUM SENSOR in Diagnostics section.)
|
|
|
Faulty vacuum sensor.
|
Replace sensor.
|
| Symptom |
Problem |
Solution |
|
No high or low population reading.
|
Dirty seed tube sensors.
|
Clean sensors. (See Seed Tube Sensors section.)
|
|
|
No radar speed.
|
Connect and calibrate radar or other speed source.
|
|
|
Seed sensors turned off.
|
Turn split row option off. (See CONFIGURE FRAME, SPLIT ROW, AND DRIVE DISCONNECT WARNING in SETUP Basic Planter Configuration section.)
|
|
|
|
Turn rows on. (See SEED SENSORS ON/OFF in SETUP Basic Planter Configuration section.)
|
|
|
Faulty wire harness connection.
|
Check wiring harness connections.
|
|
|
|
Correct wire harness connection. See Technical Manual TM1023.
|
| Symptom |
Problem |
Solution |
|
Wrong population reading.
|
Dirty seed tube sensors.
|
Clean sensors. (See Seed Tube Sensors section.)
|
|
|
Row spacing incorrect.
|
Enter correct row spacing. (See CONFIGURE FRAME, SPLIT ROW, AND DRIVE DISCONNECT WARNING in SETUP Basic Planter Configuration section.)
|
|
|
Speed reading incorrect.
|
Enter correct radar calibration or troubleshoot radar.
|
|
|
Windy or dusty conditions.
|
Change to a speed source other than radar. (See GROUND SPEED SOURCE in SETUP Basic Planter Configuration section.)
|
|
|
Wrong units of measure.
|
Enter correct units. (See CONFIGURE LANGUAGE AND UNITS OF MEASURE in Monitor Settings section.)
|
|
|
Speed reading too high.
|
See wrong speed reading above.
|
|
|
Planting seed at a rate exceeding sensor capability.
|
Install AccuCount™ sensors or use Population Adjust.
|
|
|
Planting Hill-Drop cotton.
|
Multiple seeds pass seed sensor at one time.
|
|
Row failure warning.
|
Meter not planting.
|
Seed hopper empty, fill with seed.
|
|
|
Harness problem.
|
Inspect harness and connections.
|
|
|
Planting in rocky conditions.
|
Seeds knocked off disk, adjust row unit down force.
|
|
|
Dirty seed tube sensors.
|
Clean sensors. (See Seed Tube Sensors section.)
|
| Symptom |
Problem |
Solution |
|
Wrong area reading.
|
Planter width incorrect.
|
Enter correct planter width. (See CONFIGURE FRAME, SPLIT ROW, AND DRIVE DISCONNECT WARNING in SETUP Basic Planter Configuration section.)
|
|
|
Half-width or third-width disconnect on.
|
Select "Reduce Area by these Rows" when using disconnect feature.
|
|
|
Radar problem.
|
Correct radar calibration or troubleshoot radar.
|
|
No planter monitor reading.
|
Electrical connections not correct.
|
Check fuses in tractor. Check connections on back of rear tractor connector. C and D connections must be tight (C-red, D-black). Remove splash-shield by inserting finger and prying up on front of cover to remove. Insert wires in C and D until tight. Pin removal tool will be required if wires are in wrong position.
|
|
No liquid fertilizer reading.
|
There is no pressure.
|
Drive planter forward and verify pump is primed.
|
|
|
Incorrect planter options.
|
Enter correct number of fertilizer sensors. (See LIQUID FERTILIZER SENSORS in SETUP Basic Planter Configuration.)
|
|
|
Sensor connected to wrong wire harness lead.
|
If only one liquid sensor is used, it must be connected to wire labeled LEFT FERT.
|
|
|
Faulty wire connection.
|
Check wiring harness and repair.
|