Troubleshooting Conveyance System

Symptom Problem Solution

Auger flighting or conveyor belt does not turn, or turns slow.

Low hydraulic oil level.

Check and fill reservoir.

Pressurized return line.

Reverse hose connections to tractor or move control lever in opposite direction.

Tractor control valve return line closed.

Cycle tractor control lever in opposite direction momentarily to open.

Tractor flow control set too low.

Increase valve setting.

Tractor pressure too low.

Check and repair tractor hydraulic system. See your John Deere dealer.

Selector valve set for FAN.

Pull valve handle out for AUGER operations.

Drive coupler damaged.

Replace coupling hardware.

Damaged shaft seal.

See your John Deere dealer.

Faulty selector valve.

Repair or replace valve. See your John Deere dealer.

Faulty control valve.

Repair or replace valve. See your John Deere dealer.

Faulty drive motor.

Repair or replace motor. See your John Deere dealer.

Conveyor belt slips

Tension belt. See procedure in Service section

Auger spout hose plugs during fill.

Hose is too long.

Shorten hose to desired length.

AG,OUO6023,1196 -19-02JUN09-1/1