Fan motor leaks.
|
Case drain line crimped, not connected to low-pressure port, or connected to wrong port with high back-pressure.
|
Repair fan motor.
To avoid future failures, be sure to connect drain line to low-pressure (sump) return on tractor.
|
|
Fan not turning.
|
Low hydraulic oil level.
|
Check and fill reservoir.
|
|
|
Pressurized return line.
|
Reverse hose connections to tractor.
|
|
|
Selector valve set for AUGER.
|
Push valve handle in for FAN operation.
|
|
|
Tractor control valve return line not open.
|
Cycle tractor control lever in opposite direction momentarily.
Connect hoses so fan turns in proper direction when SCV lever is held in forward position.
|
|
|
Faulty selector valve.
|
Repair or replace valve. See your John Deere dealer.
|
|
|
Fan motor seal leaking.
|
Replace seal. See your John Deere dealer.
|
|
|
Faulty fan motor.
|
Repair or replace motor. See your John Deere dealer.
|
|
Fan vibrates.
|
Dirty fan blades.
|
Clean fan.
|
|
|
Broken fan blades; fan out of balance.
|
Replace fan assembly.
|
|
Fan speed too slow.
|
Tractor flow control set too low.
|
Increase valve setting.
|