Uneven or Inaccurate metering or product delivery.
|
Air leaking past lid seal.
|
Adjust lid closing down pressure.
Replace seal.
|
|
|
Product level too low for accurate metering.
|
Do not run tank empty. Refill sooner.
|
|
|
In-tank pressure tubes (ladder rails), air control valves, or manifold end cap screens plugged.
|
Clean tubes, air valves, and screens.
|
|
|
Tank pressurization hoses plugged.
|
Clean hoses.
|
|
|
Half-width disconnects closed or partially closed.
|
Completely open both disconnects.
|
|
|
Foreign material blocking product passages.
|
Remove blockage. Use screens when filling tanks.
|
|
|
Lumps in seed or fertilizer.
|
Use clean seed.
Reset agitator shaft action.
|
|
|
|
Remove lumps from fertilizer. Use screens when filling tanks.
|
|
|
Meter segment rings not installed or wrong number installed.
|
Install correct number of fine tuning rings for secondary header ports.
|
|
|
Improper assembly of header ring or air system.
|
Reassemble correctly.
|
|
|
Slide or manifold bypass openings plugged.
|
Clean openings.
|
|
|
AG,OUO6023,1200 -19-02JUN09-1/4
|
| Symptom |
Problem |
Solution |
|
No product delivery with clutches engaged.
|
Meter overload; drive pin sheared.
|
Replace sheared drive pin with 3.2 mm diameter cotter pin. (See Operate Machine-Meters section.)
Engage meter only when fan is running to avoid overload.
|
|
|
Product binding in meter rollers.
|
If binding occurs with small seed (less than 6 mm [1/4 in.]), the black meter roller, and small wear plate, switch to standard wear plate.
|
|
|
|
If binding occurs with small seed (approaching 6 mm [1/4 in.]), the black meter roller, and standard wear plate, switch to green meter roller.
|
|
|
Manifold slide in wrong position.
|
Position slide correctly.
|
|
|
Half-width disconnects closed, blocking product from meter.
|
Open half-width disconnects.
|
|
|
Large product bridging meter entry.
|
Install agitators over active runs to keep product free flowing.
|
|
|
AG,OUO6023,1200 -19-02JUN09-2/4
|
| Symptom |
Problem |
Solution |
|
Delivery rate above or below expected rate.
|
Tank not pressurized.
|
Adjust lid closing down pressure.
Check and replace lid seal.
Clean in-tank pressure tubes (ladder tubes), air control valves, and manifold end cap screens.
Clean tank pressurization hoses.
|
|
|
No meter doors installed.
|
Install doors on inactive runs.
|
|
|
Incorrect transmission setting.
|
Review rate chart and set transmission.
Perform meter calibration.
Check tire speed sensor gap and calibration.
|
|
|
Wrong meter rollers for product in use.
|
Replace meter segments with correct rollers for desired application rate.
Check transmission settings.
Check monitor set-up and calibration.
|
|
|
Inaccurate rate check results.
|
Rerun rate check.
|
|
|
Plugged product passages or meter roller flutes.
|
Check and remove caked product from passages and meter rollers.
|
|
|
Wrong drive sprockets installed.
|
Change sprockets to agree with rear tire size and row spacing.
|
|
|
Transmission crank turned in wrong direction during calibration.
|
Perform rate check. Turn crank counterclockwise.
|
|
|
Slide or manifold bypass openings plugged.
|
Clean openings.
|
|
|
Manifold slide in wrong position.
|
Position slide correctly.
|
|
|
AG,OUO6023,1200 -19-02JUN09-3/4
|
| Symptom |
Problem |
Solution |
|
|
Half-width disconnects not fully open.
|
Move handles down to open product passages. Perform rate check.
|
|
|
Variable rate not established.
|
Build rate selection menus. Perform variable rate set-up.
|
|
|
Desired rates exceed capacity.
|
Reduce speed or add more primaries.
|
|
Manifold slide difficult to move.
|
Foreign objects in slide path
|
Inspect for and remove foreign objects.
|
|
|
Material collects on slide.
|
Tap lightly on slide handle. Remove slide and coat with a PTFE or graphite lubricant.
|
|
|
AG,OUO6023,1200 -19-02JUN09-4/4
|
|