Clean Seed Tube Sensor

A30007-UN-06OCT88
It is possible for dusty conditions or heavily treated seed
to cause an excessive buildup of dust and seed treatment inside the
seed tubes that blocks the seed sensor light. When the sensor light
becomes blocked, false low population counts or false low limit warnings
appear.
Periodically clean the seed sensor area inside seed tube with
dry brush provided.
IMPORTANT: Do not plant again until all interior seed tube surfaces
are dry.
If moisture enters the seed tube during a rain or when machine
is washed, dust in the seed tubes turns to mud. If moisture is present
or dry residue is difficult to remove with a dry brush, use mild detergent
and water with brush. Allow interior seed tube surfaces to dry.
|
|
OUO6045,00000D2-19-20090202
|
|