Finger Pick-Up Meter
IMPORTANT:
Never turn finger pick-up meter backward. Damage to brush will result.
Empty finger pick-up of all corn, chaff, and foreign material every 50 hours of use. Remove seed hopper from row unit and dump all material. Baffle covering fingers must also be emptied. Rotate finger pick-up several revolutions by hand to free any corn or foreign material from beneath fingers and empty this material before replacing seed hopper on planting unit.
To thoroughly inspect finger pick-up mechanism, see FINGER PICK-UP MECHANISM in Service-Every 100 Hours section.
|