Markers

Symptom Problem Solution

Marker will not lower.

Marker valve set to "Off".

Set to "On".

Orifice in marker cylinder plugged.

Clean or replace orifice.

Markers not alternating.

Marker hoses not connected to marker valve correctly.

Connect hoses to proper locations.

Air in marker valve.

Bleed marker hydraulic system.

Marker valve defective.

Replace or repair valve. See your John Deere dealer.

Marker floats off ground.

Air in hydraulic system.

Bleed marker lift cylinder.

Alternator valve defective.

Replace valve. See your John Deere dealer.

Marker cylinder orifice plugged.

Clean or replace orifice.

SCV metering valve set to low.

Adjust valve.

Leak in marker cylinder.

Repair or replace.