Check Fertilizer Opener Offset
Fertilizer can be placed from 63 mm to 102 mm (2.5 in. to 3.5 in.) to the outside of the row in most locations. After any change in location, raise and lower machine slowly and watch for interference.
1.
Lower machine until fertilizer openers and seed openers just touch the ground.
2.
Drive forward 3.7 m (12 ft.) with machine in this position.
3.
Measure distance between fertilizer opener and seed opener.
4.
Adjust fertilizer openers as needed. See Fertilizer Opener sections for procedure on unit installed on machine.
|