CAUTION: Avoid serious injury from exploding parts due to overpressurization or operating the system without all components in place.
Do not inflate system above 827 kPa (8.2 bar) (120 psi).
Do not remove pressure relief valve.
Do not pressurize system unless all row unit components are in place.
IMPORTANT: Do not operate a pinched or unrolled air bag . Lower system pressure until air bags can be rolled by hand. Roll air bag back over lower piston. Incremental lowering of machine is required to get rubber started rolling over the lower piston.
Pressurize system to a minimum of 83 kPa (0.8 bar) (12 psi) before raising or lowering machine.