Vacuum SensorsNOTE: This option is only visible if machine is configured for one or more vacuum sensors.  A59325-UN-19FEB07
Menu  A59551-UN-08MAR07
Planter Button  A59172-UN-29JAN07
Configuration Softkey  A59369-UN-20FEB07
Zero Sensor Button Select Menu >> Planter button >> Configuration softkey >> Sensor tab.
Select Vacuum from drop down box. Select number of vacuum sensors on machine from Sensors: drop down box. NOTE: Current pressure is displayed on bottom left of screen. Select each sensor, one at a time, from the Sensor drop down box. Shut off vacuum hydraulics prior to depressing the Zero Sensor button.
Screen Area Information Planter Configuration - Planter Configuration Sensor - Sensor Vacuum - Vacuum Sensors: - Sensors: Sensor - Sensor Cal Value - Calibration Value Turn Vacuum Off - Turn Vacuum Off Select - Select | OUO6064,00000F4-19-20100615 |
|