Configure RowCommand™

  1. A59325
    A59325-UN-19FEB07

    Menu

    A59551
    A59551-UN-08MAR07

    Planter Button

    A59172
    A59172-UN-29JAN07

    Configuration Softkey

    A59377
    A59377-UN-23FEB07

    Settings Button

    A62277
    A62277-UN-23JUL08

    Next Page

    H85801
    H85801-UN-14JUN06

    Enter

    Select Menu >> Planter button >> Configure softkey >> Drives tab >> Drive Sections drop-down box >> Settings button.



  2. Check RowCommand™ box to enable. Select Next Page icon.

    NOTE: To set up motors see CONFIGURE PLANTER DRIVE SOURCE section in this manual.

  3. If equipped with variable drive, motor setup appears on screen. Select Next Page icon until row control sections setup appears on screen:

    1. Enter number of RowCommand™ control sections in input box. Select Next Page icon.

      IMPORTANT: RowCommand™ sections must not cross meter drive sections on the planter. Plan your configuration accordingly. See RECOMMENDED ROWCOMMAND™ CONFIGURATIONS in this section.

      IMPORTANT: The number of rows across a minimum of 152 cm (60 in.) must be entered for each section. If planter is on 76 cm (30 in.) row spacing a minimum of 2 rows must be entered.

      For example if a 1790-16/32 is being set up, there are four rows per 152 cm (60 in.), minimum number of rows per section would be four.

      IMPORTANT: If numerous RowCommand™ clutches are simultaneously energized (meters disengaged), a tractor “Low Voltage” warning may occur due to limited alternator output. Reduce electrical load or increase engine RPM.

    2. Configure each sections ending row using input box. Select Next Page icon to toggle through each section. See RECOMMENDED ROWCOMMAND™ SECTION CONFIGURATIONS in this section.

    3. When complete, a visual representation of the configuration appears. Select Enter to confirm setup. Select Enter again. Cycle power when prompted.

    To edit row control sections select Menu >> Planter button >> Configure softkey >> Drives tab >> Row Control Sections drop-down box >> Settings button.

    If Row Control Sections does not appear in drop-down box, RowCommand™ has not been enabled. Repeat RowCommand™ configuration procedure.

  4. Calibrate start and stop height for planter. See CALIBRATE COMMON START AND STOP HEIGHT or CALIBRATE SEPARATE START AND STOP HEIGHT in the SeedStar™ 2 SETUP Basic Planter Configuration Section.

Screen Area Information

Planter Configuration - Planter Configuration
Drives - Drives
Row Command - Row Command
Number of Sections - Number of Sections
Start Row - Starting Row
End Row - Ending Row
Row Control Sections - Row Control Sections

OUO6064,0000183-19-20100720