Warning Screens for SeedStar™ XP A68149-UN-13JUL10 PM2 Sensor voltage supply #1 out of range.5VDC sensor supply voltage on PM2 out of range high or low. Check wire harness and connectors for damage.  A68151-UN-13JUL10 Left CAN bus subnet address circuit error. Check electrical connections.Check wire harness and connectors for damage. See your John Deere™ dealer.  A68152-UN-13JUL10 Right CAN bus subnet address circuit error. Check electric connections.Check wire harness and connectors for damage. See your John Deere™ dealer.  A68153-UN-13JUL10 Communication error. Seed monitor is offline.PM2 controller is online but does not detect PM1 controller on the CAN Bus. Cycle key switch power and wait for system to load. See your John Deere™ dealer.  A68154-UN-13JUL10 Communication error. Seed monitor online but not responding to CAN bus messages.PM2 detects PM1 controller on the CAN Bus, but PM1 controller is not responding. Cycle key switch power and wait for system to load. See your John Deere™ dealer.  A68155-UN-13JUL10 9 pin connector voltage out of range. Check pins 1 and 3.Voltage across pin 1 (ground) and pin 3 (12VDC) of 9 pin ISO connector is out of range high or low. Check wire harness and battery connections.  A68156-UN-13JUL10 9 pin connector voltage not detected. Check pins 1 and 3.No voltage is present across pin 1 (ground) and pin 3 (12VDC) of 9 pin ISO connector. Refer to tractor operator’s manual and check fuses.  A68157-UN-13JUL10 CAN bus subnet communication error. These sensor nodes are offline:1,2,3,4,5,6,7 Sensor node controllers listed are offline. Check wire harness and connectors for damage. See your John Deere™ dealer.  A68158-UN-13JUL10 CAN bus subnet communication error. These sensor nodes are online but not responding to CAN bus messages:1,2,3,4,5,6,7 Sensor node controllers listed are online, but not communicating with the PM2 controller. See your John Deere™ dealer.  A68159-UN-13JUL10 Row unit dynamic sensor error on these sensor nodes:1,2,3,4,5,6,7 There is a problem with the dynamics sensor inside the sensor node controllers listed. See your John Deere™ dealer.  A68160-UN-13JUL10 Gauge wheel load sensor circuit error. Check electrical wiring.These load sensors are responding in error: 1,2,3,4,5,6,7 The sensor node controllers listed are detecting a problem with the gauge wheel load sensor. Check load sensor wire harness for damage.  A68161-UN-13JUL10 PM2 controller ECU voltage out of range. Check electrical wiring.12 VDC power for PM2 controller out of range high or low. See your John Deere™ dealer. | OUO6064,000020A-19-20100729 |
|