Timed Seed Drop Test

  1. A59325
    A59325-UN-19FEB07

    Menu

    A59551
    A59551-UN-08MAR07

    Planter Button

    A59567
    A59567-UN-08MAR07

    Diagnostic Softkey

    Select Menu >> Planter button >> Diagnostics softkey >> Tests tab.



  2. Select Timed Seed Drop from drop down box.

  3. Select Row input box and enter a row unit number to observe.

  4. Select Time input box and enter number of seconds to perform test.

  5. Plant at preferred speed and select Start button.

  6. Time will count down to zero and test will stop. Select Stop button to stop test before time reaches zero.

  7. Observe seed count on screen.

Screen Area Information

Planter Diagnostics - Planter Diagnostics
Tests - Tests
Timed Seed Drop - Timed Seed Drop
Start - Start
Stop - Stop
Row - Row
Count - Count
mph - Miles per hour
kph - Kilometers per hour
Time - Time
sec - Seconds

OUO6064,0000212-19-20100721