Liquid Fertilizer Sensor

A59325
A59325-UN-19FEB07

Menu

A59551
A59551-UN-08MAR07

Planter Button

A59172
A59172-UN-29JAN07

Configure Softkey

Use this to verify proper sensor connection and calibration.

  1. Turn tractor OFF. Turn key to ACC.

  2. Verify sensor wiring is properly connected.

    If only one sensor is used, it MUST be connected to LEFT FERT wire.

  3. Verify correct number of sensors are selected.

    Select Menu >> Planter button >> Configuration softkey >> Sensor tab >> Fertilizer drop down.

    Number of Sensors selected must match number of sensors on machine.

    Select Sensor drop down and select each sensor one at a time. Select Cal Value and enter 37.50 (English units) or 258.55 (Metric units).

  4. Release trapped pressure in fertilizer system. Select each sensor one at a time and select Zero Sensor button.

  5. Verify voltages are correct.

    Select Diagnostic softkey >> Readings tab >> System Voltages drop down.

    • Controller Input value MUST be 11 vdc or higher.
    • Fertilizer Sensor Supply value is 8.0 vdc.
    • If voltage is ZERO, check wiring.

Screen Area Information

Planter Configuration - Planter Configuration
Sensor - Sensor
Fertilizer - Fertilizer
Sensors - Sensors
Sensor - Sensor
Cal Value - Calibration Value
Pressure - Pressure
Planter Diagnostics - Planter Diagnostics
Readings - Readings
System Voltages - System Voltages
Controller Input - Controller Input
Fertilizer Sensor Supply - Fertilizer Sensor Supply
V - Volts

OUO6064,0000214-19-20100729