Rotate Seed Meters

A59325
A59325-UN-19FEB07

Menu

A59551
A59551-UN-08MAR07

Planter Button

A59567
A59567-UN-08MAR07

Diagnostic Softkey

A59898
A59898-UN-02APR07

Meter Rotation Button

Use this to verify drillshaft and meters turn without pulling machine through a field. Planter remains stationary during this test.

  1. Select Menu >> Planter button >> Diagnostics softkey >> Tests tab.

  2. Select Rotate Meters from drop down box.

  3. Select Motor Selection input box and select All or any single motor to rotate.

  4. The following must occur for this feature to function:

    • Planter must be unfolded.
    • Planter must be in raised position.
    • Planter must be stationary.
    • Variable rate hydraulics must be active.

Select Meter Rotation button. An audible tone sounds when meters stop turning. Each time the icon is pressed, the meters rotate approximately one half a revolution. If meters fail to move, a warning screen appears.

Rotate Seed Meter function can be accessed from the planter main Run page.

Screen Area Information

Planter Diagnostics - Planter Diagnostics
Tests - Tests
Rotate Meters - Rotate Meters
Motor Selection - Motor Selection
All - All
Ground Speed - Ground Speed
mph - Miles per hour
kph - Kilometers per hour
Wheel Sensor - Wheel Sensor
Active - Active
Inactive - Inactive
Planter Position - Planter Position
Up - Up
Down - Down
Motor - Motor
Target rpm - Target revolutions per minute
Actual rpm - Actual revolutions per minute
Valve % - Valve percentage

OUO6064,0000218-19-20100721