Variable Rate Drive Component Activity A59325-UN-19FEB07
Menu  A59551-UN-08MAR07
Planter Button  A59567-UN-08MAR07
Diagnostic Softkey The Variable Rate Drive Data Screen is the single best source to diagnose VRD problems. The following must occur for the VRD system to operate.- A target population must be entered and turned "ON".
- VRD hydraulics must be flowing continuously at highest flow rate.
- Planter must be unfolded and lowered to planting height.
- Height sensor must be calibrated and "Planter Position" must indicate "Down".
- Planter must be moving forward at planting speed.
- "Ground Speed" must indicate a ground speed.
- "Wheel Sensor" must indicate "Active".
NOTE: If Target RPM displays CAL, operate machine in the field a short distance with VRD active. This calibrates motors. Select Menu >> Planter button >> Diagnostics softkey >> Readings tab. Select VRD Data from drop down box. The status and activity for VRD components is shown.
Screen Area Information Planter Diagnostics - Planter Diagnostics Readings - Readings Variable Rate Drive Data - Variable Rate Drive Data Target Population - Target Population seeds/ac - Seeds per acre seeds/ha - Seeds per hectare Ground Speed - Ground Speed mph - Miles per hour kph - Kilometers per hour Wheel Sensor - Wheel Sensor Active - Active Inactive - Inactive Planter Position - Planter Position Up - Up Down - Down Motor - Motor Target rpm - Target revolutions per minute Actual rpm - Actual revolutions per minute Valve % - Valve percentage Left - Left Right - Right Open - Open Closed - Closed | OUO6064,0000219-19-20100721 |
|