Quick Reference Setup for VRD Machines

A61139
A61139-UN-12OCT07

Main Menu Screen

A61140
A61140-UN-15OCT07

Planter Application Screen

A - Main Menu

B - Layout Manager

C - Performance Monitor

D - Planter Application

E - Display Application

F - Planter Main

G - Planter Configuration

H - Planter Rates

I - Planter Totals

J - Planter Diagnostics

The following reference assumes that the operator has read and understands this manual. Some button images are given on this page as a reminder. Some entries require certain information be set up first. Follow quick reference in sequence.

Quick Reference

Screen Layout

Select Menu >> Layout Manager button >> Select a layout pattern.

 

>> Screen Area

Select a screen area to assign an application.

 

>> Application Button

Only applications allowed in chosen area appear as selections. Select one.

 

>> Application Screen

Select application screen to verify. Select remaining screen areas to change. Select enter when done.

Performance Monitor

Select Menu >> Performance Monitor button >> Settings button. If monitor reset button is ever pressed, these values are erased.

 

>> Check Box

Select GPS or radar connected directly to planter application or not. Check indicates connected. Empty indicates radar is part of tractor system.

 

>> Input Box

Verify that Implement Width matches planter width shown in planter monitor. Cycle power if they do not match.

 

>> Calibrate Button

Follow calibration procedure if radar is connected to display.

Planter Drive Configuration

Select Menu >> Planter button >> Configure softkey >> Drives tab >> Drive Configuration drop-down box >> Settings button.

 

>> Drive Source

>> Variable Rate. If this is changed, all setup data is lost.

 

>> Meter Type

Vacuum or Mechanical

 

>> Drive Type

MaxEmerge™ or Pro-Series™

 

>> QS Enabled

Check indicates Quick Start enabled (recommended). Empty indicates disabled.

Planter Drive Section Configuration

Select Menu >> Planter button >> Configure softkey >> Drives tab >> Drive Sections drop-down box >> Settings button.

 

>> Number of Sections Input Box

Enter number of variable rate motors on planter if different than shown.

 

>> RowCommand™

Check indicates RowCommand™ enabled. Empty indicates disabled.

 

>> Next Page Button

Enter values for first motor in input boxes.

 

>> Next Page Button

Enter values for additional motors.

 

>> Enter Button

 

Planter RowCommand™ Configuration

Select Menu >> Planter button >> Configure softkey >> Drives tab >> Row Control Sections drop-down >> Settings button.

 

>> Number of Sections Input Box

Enter desired number of RowCommand™ control sections on machine.

 

>> Next Page Button

Enter end row for current section.

 

>> Next Page Button

Enter values for additional sections.

 

>> Enter Button

 

Planter Frame Configuration

Select Menu >> Planter button >> Configuration softkey >> Frame tab.

 

>> Rows Input Box

Enter total number of rows. Total indicates all rows, even if planter is a split row machine, and half the rows are currently inactive.

 

>> Row Spacing Input Box

Enter row spacing. Spacing is the distance between any two side by side rows. Do not skip an inactive row and measure to the next active row on split row machines.

 

>> Planter Width Input Box

Enter planter width in unit of measure shown. Cycle power.

 

>> Split Row Check Box

Check the box, if planter is a split row machine. Status does not change once set.

 

>> Clutch Check Box

Check this box if machine is equipped with multiple width disconnects and a warning is desired when some rows are inactive.

Planter Sensor Configuration

>> Sensor Tab

 

>> Seed

>> Row Input Box

Use this to set specific row sensors. Do not change split row configuration on this page. Enter row number and select row on or off check box. Repeat for additional rows. Turn all row sensors on or off at once with button on bottom of page.

 

>> Vacuum

>> Sensors: Drop Down

Select number of vacuum sensors on machine.

  

>> Sensor

Vacuum must be off. Select each sensor, one at a time, and enter Calibration Value in input box. John Deere sensors are 5.66 (English units) or 143.76 (Metric units). Select zero button to zero sensor reading. Select next sensor and repeat.

 

>> Fertilizer

>> Sensors: Drop Down

Select number of fertilizer sensors on machine.

  

>> Sensor

Residual fluid pressure must be released from system. Select each sensor, one at a time, and enter Calibration Value in input box. John Deere sensors are 37.50 (English units) or 258.55 (Metric units). Select zero button to zero sensor reading. Select next sensor and repeat.

 

>> Height (Only if RowCommand™ is enabled.)

>> Common or Separate Check Box

Common sets a single height to start and stop variable rate motors.

Separate sets individual start and stop heights for variable rate motors.

  

Calibrate full up and full down

Fully raise machine and select Raised button (up arrow). Select Enter.

Fully lower machine while driving forward in field and select Lowered button (down arrow). Select Enter.

  

Set start and stop point

Common: Select Start/Stop button. Raise machine to correct height and select Start/Stop Height button or enter a value in Input box. Select Enter.

Separate: Select Start/Stop button. From lowered position, raise machine to motor stop point and select Stop Height button or enter value in Input box. From raised position, lower machine to motor start point and select Start Height button or enter value in Input box. Select Enter.

 

Headland Suppression Warning

Suppresses Rows Not Planting Warning when planter is raised above height sensor stop point.

  

Select Menu >> Planter button >> Configure softkey >> Sensor tab

Place a check mark in Headland Warning Suppression box.

 

>> Tractor Speed

Select Auto check box to allow display to determine optimal ground speed source (recommended). If unchecked, a drop-down appears. Select drop-down menu and choose sensor source.

Seed Rate Configuration

>> Rates Softkey

 

>> Show Rates Button

(1 rate for all motors or rates for each motor.)

  

>>Change Rates Button

To change any rate.

  

>> Rate Drop Down

Select rate to change. Use rate 6 for RX.

  

>> Motor Drop Down

When equipped with multiple motors and different rates for each motor. Select motor to set a rate. Only visible if box Use one rate for all motors is not selected.

  

>> On - Off Drop Down

Set rate to appear or run screen or not.

  

>> Target Input Box

Program target rate for selected motor.

  

>> High and Low Input Box

Automatically sets ten percent over and under. Select box to change.

  

>> Enter Button

Saves program.

 

>> One Rate All Motors Check Box

Only visible if multiple motors on machine. Check for one rate across machine. Empty for different rates on each motor.

 

>> Crop Name Drop Down

Select corn, soybeans or one of the custom crop names.

  

>> Edit Crop Name

Select to edit names of crops in crop name drop down.

 

>> Disk Type Drop Down

Select type of disk or meter.

If custom is chosen, enter number of seeds/holes per revolution.

 

>> Seed Disk (Vacuum only)

Select disk installed in meter.

 

>> Population Adjust

Enter correction value after performing seed rate check in field.

 

>> Rows Planting Check Box

Only visible on split row machine configurations. Use for turning on/off split row planting. Select number of rows actively planting.

Planter Calculators

>> Totals Softkey

 

Area Calculators

>> Totals Tab

Select any input box. Change values or zero with Zero button.

 

Seed Estimator

>> Calculators Tab >> Seed Estimator

Select one of three estimators; Bag, Unit, or Weight. Enter all values and view result. See Counters and Calculators section for details.

 

Vacuum Calculator (Vacuum meters only when vacuum meters are set up)

>> Calculators Tab >> Vacuum

  

>> Top Drop Down

Select Vacuum

  

>> Seeds per kg (lb.) Input Box

Enter number of seeds per kg (lb.)

  

>> Disk Type Drop Down

Select type of disk in meter.

  

>> Seed Disk Drop Down

Select disk. Set vacuum to suggested value as a starting point.

 

Fertilizer Calculator

>>Calculators Tab >> Fertilizer

 
  

>> Model Drop Down

Select planter model.

  

>> Rate (gal/ac)

Set the rate at which fertilizer is applied.

  

Target Speed (mph)

Set the target speed the tractor will travel.

Diagnostics

 
 

>> Diagnostic Softkey >> Readings tab.

>> Hardware/Software

Provides system data. On large frame planters with more than one controller, select each controller separately from the drop down.

  

>> Sensors/Status Drop Down

Observe readings of programmed sensors.

  

>> System Voltages

Provides system data.

  

>> VRD Data Drop Down

Review sensor readings. If Target RPM displays CAL, operate machine in the field a short distance with VRD active. This calibrates motors.

 

>> Tests >> Top Drop Down

>> Seed Tube Sensor

Tests the seed sensors detected by the monitor.

  

>> Seed Drop

Tests if a seed sensor is detecting seeds accurately.

  

>> Timed Seed Drop

Tests the seed rate of a single row unit.

  

>> VRD Events Log

 
  

>> VRD Motor/Valve Flush

Used to flush air from VRD hydraulic system.

  

>> Diagnostics Code

 
  

>> Rotate Meters

Verify drillshaft and meters turn without pulling machine through field.

  

Row Clutches test

Used to electrically test each RowCommand™ row clutch circuit.

  

Row Clutch Self-test

Used to electrically test all RowCommand™ clutches.

OUO6064,000021F-19-20100729