Accessing The Vacuum Meter

  1. A38260
    A38260-UN-27NOV95

    A - Hopper Latch

    Disengage hopper latch (A). Lift hopper upward then rearward to remove from planting unit.



  2. A54242
    A54242-UN-08APR04

    A - Vacuum Hose

    Remove vacuum hose (A) from metering unit.



  3. A38890
    A38890-UN-12JAN96

    A - Retainer

    Squeeze retainer (A) and pull vacuum monitoring hose out of connector on units attached to monitor.



  4. IMPORTANT: Use precautions as recommended by chemical manufacturers when handling parts coated with seed treatments. Use proper skin, eye and respiratory protection.

    H44309
    H44309-UN-14APR92

    A - Handle

    Disengage handle (A) and swing vacuum chamber open.



AG,OUO6074,1177-19-20090409