Accessing The Vacuum Meter
-

A38260-UN-27NOV95
A - Hopper Latch
Disengage hopper latch (A). Lift hopper upward then rearward
to remove from planting unit.
-

A54242-UN-08APR04
A - Vacuum Hose
Remove vacuum hose (A) from metering unit.
-

A38890-UN-12JAN96
A - Retainer
Squeeze retainer (A) and pull vacuum monitoring hose out
of connector on units attached to monitor.
-
IMPORTANT: Use precautions as recommended by chemical manufacturers
when handling parts coated with seed treatments. Use proper skin,
eye and respiratory protection.

H44309-UN-14APR92
A - Handle
Disengage handle (A) and swing vacuum chamber open.
|
|
AG,OUO6074,1177-19-20090409
|
|