Adjust John Blue™ Fixed Rate Pump Setting Number
IMPORTANT: Avoid pump damage. Remove drive chain from piston
pump when fertilizer system is not in use.
-

A35432-UN-21DEC92
A - Adjustment Tool
B - Pin
C - Scale Ring
D - Nut
E - Pointer
F - Gauge
Use rate chart to determine PUMP SETTING number for desired
application rate.
-
Install adjustment tool (A) on pump pin (B) aligning teeth with
scale ring (C).
-
Loosen nut (D) and rotate scale ring until pointer (E) is aligned
with pump setting number on gauge (F). Tighten nut to specification.
| Item | Measurement | Specification |
|
Nut | Torque | 25
N·m (18 lb-ft) |
-
Store adjustment tool on pin located on pump mounting bracket.
|
|
OUO6064,00006F1-19-20120117
|
|