Cleaning Vacuum Manifold System
Dirt or seed innoculant/treatment may build up in vacuum manifold
system and cause low vacuum at planting units. This could result in
loss of seed metering accuracy.
CAUTION: Follow chemical manufacturer's precautions when handling
parts coated with seed treatments. Use proper skin, eye and respiratory
protection.
Clean air manifold system at least once a week during operation
or more often in severe dusty conditions.
Clean as follows:
-
Turn on vacuum blower(s) and set hydraulic flow to 75 percent.
-
One at a time, remove vacuum hoses from meters. Inspect and
clean all straw and/or foreign material from both attaching hose ends.
Shake hose for a few seconds and replace it on meter.
-
Remove end caps from manifold tubes one at a time, then reinstall.
|
|
OUO6435,0001AEC-19-20040304
|
|