Chemical Meter Maintenance
The chemical meter fluted roller wears during operation. To
maintain meter accuracy, the fluted roller should be replaced every
250 hours of use or beginning of planting season. To replace the roller,
see CLEANING INSECTICIDE AND/OR HERBICIDE HOPPERS in Service—Every
10 Hours or Daily section.
|
|