Warning Screens for SeedStar™ 2 (Machines with Single
Set-Point Pneumatic Down Force)

A68146-UN-13JUL10
Pneumatic Down Force solenoid circuit error. System control
disabled. Check electrical connectors. Open circuit or short circuit
in pneumatic down force solenoid circuit. Check wire harness and connectors
for damage. Check continuity of solenoid coils.

A68147-UN-13JUL10
Pneumatic Down Force pressure sensor circuit error.
Open circuit or short circuit in pneumatic down force pressure
sensor circuit. Check wire harness and connectors for damage.

A68148-UN-13JUL10
Pneumatic Down Force pressure sensor calibration error.
Sensor zero voltage out of range. Remove all pressure from air
spring circuit and attempt to calibrate. Call your John Deere™
dealer.

A68149-UN-13JUL10
PM2 Sensor voltage supply #1 out of range.
5 VDC sensor supply voltage on PM2 out of range high or low.
Check wire harness and connectors for damage.

A68150-UN-13JUL10
Air compressor operating time limit exceeded. Check for air
leaks.
Air compressor has been operating for more than 30 continuous
minutes. Check air lines between tank and compressor for leaks. Verify
that tank relief valve and compressor pressure switch are not leaking.

A72621-UN-19SEP11
Pneumatic down force system pressure is low. Check for air
leaks or stuck valve.
Row unit down force pressure is not in limit set on PDF air
pressure sensor setup page. Check air lines between tank and compressor
for leaks. Verify that tank relief valve and compressor pressure switch
are not leaking.

A68151-UN-13JUL10
Left CAN Bus subnet address circuit error. Check electrical
connections.
Check wire harness and connectors for damage. See your John
Deere™ dealer.

A68152-UN-13JUL10
Right CAN Bus subnet address circuit error. Check electric
connections.
Check wire harness and connectors for damage. See your John
Deere™ dealer.

A68153-UN-13JUL10
Communication error. Seed monitor is offline.
PM2 controller is online but does not detect PM1 controller
on the CAN Bus. Cycle key switch power and wait for system to load.
See your John Deere™ dealer.

A68154-UN-13JUL10
Communication error. Seed monitor online but not responding
to CAN Bus messages.
PM2 detects PM1 controller on the CAN Bus, but PM1 controller
is not responding. Cycle key switch power and wait for system to load.
See your John Deere™ dealer.

A68155-UN-13JUL10
9 pin connector voltage out of range. Check pins 1 and 3.
Voltage across pin 1 (ground) and pin 3 (12 VDC) of 9 pin ISO
connector is out of range high or low. Check wire harness and battery
connections.

A68156-UN-13JUL10
9 pin connector voltage not detected. Check pins 1 and 3.
No voltage is present across pin 1 (ground) and pin 3 (12 VDC)
of 9 pin ISO connector. Refer to tractor operator’s manual
and check fuses.

A68161-UN-13JUL10
PM2 controller ECU voltage out of range. Check electrical
wiring.
12 VDC power for PM2 controller out of range high or low. See
your John Deere™ dealer.
|
|
OUO6064,00005D4-19-20111110
|
|