Adjust Unit Mounted Single-Disk Fertilizer Opener
The unit mounted single-disk fertilizer opener is NOT recommended
for use in rocky conditions as fertilizer tubes are susceptible to
bending.
IMPORTANT: Avoid bending fertilizer tube. It is necessary to
perform final nozzle adjustments in the field. Ensure each fertilizer
nozzle is directly behind and centered over coulter furrow. Operate
machine for a short distance and check each nozzle for correct alignment.
Nozzle-to-coulter alignment is adjusted correctly when no fertilizer
splatters on coulter during operation.

A46048-UN-03APR00
A - Nozzle Tip
B - Bracket
C - Cap Screw
Select nozzle tip (A) to reach system pressures acceptable
for pump range, delivery rate, and travel speed. (See Liquid Fertilizer
Rate Charts section for proper tip.)
Set nozzle tip (A) 13 mm (1/2 in.) above soil surface with adjusting
bracket (B). Range of coulter adjustment is between zero and 51 mm
(2 in.) below seed opener depth. Coulter depth must not exceed 102
mm (4 in.) below soil surface. Adjust coulter position in relation
to seed openers with cap screws (C). Periodically check and adjust
to compensate for wear.
|
|
AG,OUO6074,1663-19-20070731
|
|