Clean Liquid Fertilizer Tank
Although the tank is made of a highly durable and corrosion
resistant plastic, proper maintenance is required.
Rinse the tank with water when changing from one solution to
another.
Rinse tank thoroughly with water after each season or before
any shutdown lasting over one week.
Do not allow sludge to accumulate in the bottom of the tank.
Do not leave fertilizer in the tank if the temperature is expected
to drop below 40 degrees as some types of liquid fertilizers will
begin to crystallize at this temperature.
To clean the tank, proceed as follows:
-
CAUTION: Do not service if system is under pressure. Never remove
tank lid to relieve pressure. Empty tank completely to relieve pressure
by reversing flow through nurse tank pump or press the spring loaded
check valve (E) on the center of the tank lid.

A49476-UN-27JUN02

A47840-UN-14NOV02

A53425-UN-02DEC03

A47843-UN-14NOV02
A - Lid
B - Strainer Cap
C - Valves
D - QUICK-FILL Cap
E - Spring Loaded Check Valve
Relieve pressure from tank.
-
Remove lid (A).
-
Remove strainer cap (B) and screen.
-
Open shutoff valves (C) going to pump, tank and QUIK-FILL port.
-
Remove QUICK-FILL cap (D).
-
Flush tank and hoses with water.
-
After cleaning tank, close shutoff valves, replace strainer
cap, QUICK-FILL cap and replace lid on tank.
-
To clean pump and distribution lines, see LIQUID FERTILIZER
SYSTEM WITH PISTON PUMP in Storage section.
|
QUIK-FILL is
a trademark of Deere & Company
|
OUO6074,00008DF-19-20090522
|
|