| Symptom | Problem | Solution |
|
Marker floats off ground.
| Machine not down. |
Machine must be fully
lowered for proper marker operation.
|
|
Markers not alternating in automatic mode.
| Marker alternating switch on wheel module seven out
of adjustment. |
Fully raise machine
and check marker alternating switch adjustment. See ADJUST MARKER
ALTERNATING SWITCH in Service and Adjustments section.
|
|
Left marker lowers when not selected.
| Valve S5 stuck open. |
Check for 12 volts at
solenoid.
Check solenoid.
|
|
Right marker lowers when not selected.
| Valve S6 stuck open. |
Check for 12 volts at
solenoid.
Check solenoid.
|
|
Left marker will not lower.
| No power to control box. |
Check seven pin connector.
Check in-line fuses.
|
| |
Valve S5 not energized.
|
Check for 12 volts at
solenoid.
Check solenoid.
|
| |
Valve S5 is stuck closed.
|
Clean or replace valve.
|
| |
Check position of switches on frame control box.
|
Activate correct switches.
|
| |
Check frame fold switch in pivot area.
|
Broken wires.
Carrier damaged or jammed.
|
|
Right marker will not lower.
| No power to control box. |
Check seven pin connector.
Check inline fuses.
|
| |
Valve S6 not energized.
|
Check for 12 volts at
solenoid.
Check solenoid.
|
| |
Valve S6 is stuck closed.
|
Clean or replace valve.
|
| |
Check position of switches on frame control box.
|
Activate correct switches.
|
| |
Check frame fold switch in pivot area.
|
Wires damaged or cut.
Carrier jammed.
|
|
Marker lowers and disk blade is forced into the ground.
| Marker cylinder is not floating in J-slot. |
Lengthen marker hydraulic
hoses.
|
|
Marker operating too fast.
| Verify that there is an orifice fitting in the rod end
of the cylinder. |
Install orifice fitting
in rod end of the cylinder.
|
| |
Air in hydraulic system.
|
Disconnect and cycle
cylinder to eliminate air.
|
|
Shear bolt shears too often.
| Marker disk angle too aggressive. |
Reduce angle of marker
disk blade. See ADJUST MARKER DISK in Service and Adjustments section.
|
|
Cannot see marker mark in field.
| Marker disk angle not aggressive enough. |
Increase angle of marker
disk blade. See ADJUST MARKER DISK in Service and Adjustments section.
|
|
|
OUO6435,0001F58-19-20090515
|
|