Electric Drive System

SymptomProblemSolution

Meters stop running on the entire planter

Meter binding

Remove object that is binding meter. Adjust meter if binding on inner components. Check meter is working correctly by performing meter or planter runoff.

 

Seed Jamming in meter

Remove seed jammed from meter. Check meter is working correctly by performing meter or planter runoff.

 

Debris in meter

Remove debris from meter. Check meter is working correctly by performing meter or planter runoff.

 

Hub height adjustment too tight

Adjust hub height. Check meter is working correctly by performing meter or planter runoff.

 

Torque is too high on-screen

Check for possible obstruction inside meter. Remove objects. Possibly adjust meter hub. Check meter is working correctly by performing meter or planter runoff.

WP29706,00003FC-19-20140923