Raise and Lower Machine
IMPORTANT: Case drain hose must be connected or damage to machine
occurs.
IMPORTANT: Avoid machine damage. Do not place SCV in “Float”
position to lower machine. Machine must be powered up and down.
Move SCV I rearward to extend lift cylinders and raise machine.
Move SCV I forward to retract lift cylinders and lower machine.
After raising or lowering machine, hold SCV for approximately
5 seconds to verify machine raises and lowers completely.
To avoid plugging seed and fertilizer openers, verify that machine
is moving forward when raising or lowering in the unfolded position.
SCV I must be in continuous forward detent position when lowering
machine for planting. CCS fan operates only when SCV I, is in forward
detent.
NOTE: To improve raise-lower cycle time, set the raise detent
time to 3 or 4 seconds to raise planter approximately 50-60% height
on end turns. Lower detent must be set to continuous in order to supply
oil to the CCS and down force compressor circuit while planting.
NOTE: See tractor Operator's Manual for instructions for setting
independent SCV extend and retract detent settings.
When planter is raised in the unfolded position, do not leave
SCV in raise detent (continuous flow) for an extended period. Normal
leakage in the planter hydraulic system allow the center frame to
raise beyond normal field transport height.
|
|
WP29706,000078E-19-20140912
|
|