Checking Tractor Hydraulic System
IMPORTANT: Do not use an open center tractor hydraulic system
for operating machine. Permanent damage to tractor pump results.
For complete tractor operating instructions, refer to the tractor
operator's manual.
The CCS fan, vacuum motor, and electric power generation systems
are operated with closed-center tractor hydraulic systems. (Tractors
with load sensing or pressure on-demand hydraulics are classified
as closed-center systems). Open center tractor hydraulics are NOT
compatible with system.
A minimum tractor standby pressure required to operate the CCS
fan, vacuum motor, and electric power generation hydraulic systems.
The minimum tractor standby pressure required is approximately 15
513 kPa (155 bar) (2250 psi). The pressure is also dependent on frame
configuration, planting speed, and number of rows on machine.
Hydraulic system working pressure is 20 684 kPa (207 bar) (3000
psi). Hydraulic system burst pressure is 82 737 kPa (827 bar) (12
000 psi).
|
|
WP29706,00007FC-19-20140919
|
|