Vacuum Sensor Calibration
-
NOTE: This option is only visible if machine is configured for
one or more vacuum sensors.

A59325-UN-19FEB07
Menu

A59551-UN-08MAR07
Planter Button

A59172-UN-29JAN07
Configuration Softkey

A59369-UN-20FEB07
Zero Sensor Button
Select Menu >> Planter button >> Configuration softkey
>> Sensor tab.
-
Select Vacuum from drop down box.
-
Select each sensor, one at a time, from the Sensor drop down box.
-
Select Cal Value input box and enter
the number of inches of water displayed per volt from the vacuum sensor. John Deere planters
with factory equipped sensors have a calibration value of 5.66 (English
units) or 143.76 (Metric units).
-
NOTE: Current pressure is displayed on bottom left of screen.
Shut off vacuum hydraulics prior to depressing the Zero Sensor button.
Screen Area Information
Planter Configuration - Planter Configuration
Sensor - Sensor
Vacuum - Vacuum
Cal Value - Calibration Value
Turn Vacuum Off - Turn Vacuum Off
Select - Select
|