System Components

A63336-UN-02OCT08
RowCommand™ Electronic Power Module
RowCommand™ Electronic Power Module
The Electronic Power Module receives CAN Bus messages from the
Planter Main 1 (PM1) controller and switches electrical power to the
RowCommand™ clutches on and off.

A67674-UN-11JUN10
MaxEmerge™ Pro-Shaft RowCommand™ Clutch
MaxEmerge™ Pro-Shaft RowCommand™ Clutch
The RowCommand™ Clutch is engaged (seed meter turning)
when there is no electrical power applied to the clutch solenoid.
The clutch is disengaged when the electronic power module (EPM) supplies
electrical power to the clutch solenoid.

A67675-UN-11JUN10
MaxEmerge™ Chain Driven RowCommand™
Clutch
MaxEmerge™ Chain Driven RowCommand™ Clutch
The RowCommand™ Clutch is engaged (seed meter turning)
when there is no electrical power applied to the clutch solenoid.
The clutch is disengaged when the electronic power module (EPM) supplies
electrical power to the clutch solenoid.

A67676-UN-11JUN10
Pro-Series Pro-Shaft RowCommand Clutch
Pro-Series Pro-Shaft RowCommand™ Clutch
The RowCommand™ Clutch is engaged (seed meter turning)
when there is no electrical power applied to the clutch solenoid.
The clutch is disengaged when the electronic power module (EPM) supplies
electrical power to the clutch solenoid.
|
|
OUO6064,00001AA-19-20100720
|
|