Warning Screens for RowCommand™

A61426-UN-19NOV07
The height sensor is not calibrated.
The height sensor must be calibrated before the system operates
correctly.
Refer to height sensor calibration procedures in SETUP BASIC
PLANTER CONFIGURATION section of this manual.

A61427-UN-19NOV07
A stop point less than 20 is not recommended.
If the stop point is set too low, there is potential for the
drives to shut off when traveling over uneven terrain.

A63767-UN-07NOV08

A63768-UN-07NOV08
No CAN Bus communications with Electronic Power Modules (EPM).
Some row clutches do not disengage.
Check connections. A restart is required to reattempt communications
with EPMs.
Warning screen lists EPMs that are currently offline. Control
section status bars associated with offline EPMs disappear from Main
run page and half-page split run page.

A63769-UN-07NOV08
Electronic Power Modules (EPM) are not responding to CAN
Bus commands. Some row clutches do not disengage.
Check connections. A restart is required to reattempt communications
with EPMs.
Warning screen lists EPMs that are currently not communicating.

A63770-UN-07NOV08
Low Supply Voltage on Electronic Power Modules (EPM). Clutch
system self-test is not available.
Warning screen lists EPMs with supply voltage less than 10.5
V.

A63771-UN-07NOV08
Supply Voltage Out of Range on Electronic Power Modules (EPM).
Clutch system self-test is not available.
Warning screen lists EPMs with supply voltage less than 9.0
V.

A63776-UN-11NOV08
Row Clutch Diagnostic Self-test at Startup.
Once EPMs are determined to be online and communicating, system
performs test and indicates “These row clutches are not operational”,
followed by a list.

A63778-UN-10NOV08
Control section is OFF, but some rows still planting. Check
seed sensor or row clutch.
|
|