Rotate Seed Meters

A59325-UN-19FEB07
Menu

A59551-UN-08MAR07
Planter Button

A59567-UN-08MAR07
Diagnostic Softkey

A59898-UN-02APR07
Meter Rotation Button
Use this to verify drillshaft and meters turn without pulling
machine through a field. Planter remains stationary during this test.
-
Select Menu >> Planter button >> Diagnostics softkey
>> Tests tab.
-
Select Rotate Meters from drop down
box.
-
Select Motor Selection input box and
select All or any single motor to rotate.
-
The following must occur for this feature to function:
-
Planter must be unfolded.
-
Planter must be in raised position.
-
Planter must be stationary.
-
Variable rate hydraulics must be active.
Select Meter Rotation button. An audible
tone sounds when meters stop turning. Each time the icon is pressed,
the meters rotate approximately one half a revolution. If meters fail
to move, a warning screen appears.
Rotate Seed Meter function can be accessed from the planter
main Run page.
Screen Area Information
Planter Diagnostics - Planter Diagnostics
Tests - Tests
Rotate Meters - Rotate Meters
Motor Selection - Motor Selection
All - All
Ground Speed - Ground Speed
mph - Miles per hour
kph - Kilometers per hour
Wheel Sensor - Wheel Sensor
Active - Active
Inactive - Inactive
Planter Position - Planter Position
Up - Up
Down - Down
Motor - Motor
Target rpm - Target revolutions per minute
Actual rpm - Actual revolutions per minute
Valve % - Valve percentage
|
|
OUO6064,0000218-19-20100721
|
|