Ground Driven Machines—Target Population and High-Low
Warnings
-
IMPORTANT: Population and High-Low warnings are entered differently
for variable rate drive machines. See VRD MACHINES—CONFIGURE
METER, CROP, DISK, AND RATES in this section.

A59325-UN-19FEB07
Menu

A59551-UN-08MAR07
Planter Button

A59173-UN-29JAN07
Rates Softkey
Select Menu >> Planter button >> Rates softkey.
-
Select Crop Name drop down box and
choose corn, soybeans, or one of the custom crop names.
-
Select Edit Crop Name button to change
crop name.
-
Select Target Rate input box and enter
value.
-
High and low warning limits are automatically set to a percentage
above and below the target rate. To change limits, select High and Low Warning input boxes and enter new value.
NOTE: Rates and warning setpoints are saved for each crop name.
-
Select Population Adjust input box
and enter value.
-
NOTE: Number of rows planting check boxes are only visible if
monitor is configured for a split row and twin row machines. (See
CONFIGURE FRAME LAYOUT, ROW LAYOUT, AND DRIVE DISCONNECT WARNING in
SETUP Initial System Configuration section.)
NOTE: To ensure all settings update; actively select the rows
planting check box even if a check mark is already in the box.
Select Rows Planting check box for
appropriate rows planting configuration.
Screen Area Information
Planter Rates - Planter Rates
Crop Name - Crop Name
Corn - Corn
Soybeans - Soybeans
Custom - Custom
Edit Crop Name - Edit Crop Name
Target Rate - Target Rate
High Warning - High Warning
Low Warning - Low Warning
Population Adjust - Population Adjust
Rows Planting - Rows Planting
Avg. Spacing - Average Spacing
Seeds - Seeds
ac - Acre
|
|
OUO6064,000037F-19-20130301
|
|