A59325-UN-19FEB07
Menu

A59551-UN-08MAR07
Planter Button

A59173-UN-29JAN07
Rates Softkey
Select Menu >> Planter button >> Rates softkey.
-
Select Crop Name drop down box and
choose corn, soybeans, or one of the custom crop names.
-
Select Edit Crop Name button to change
crop name.
-
Select Show Rates button.
-
Select Change Rates button.
-
If setting different rates for each motor, select Motor drop down box to choose a motor to assign
rates.
NOTE: Each motor must have a rate set for each rate selected.
-
Select Rate drop down box and choose
a rate to assign population.
-
Select Target input box and enter
the target population for selected rate. High and Low population (warning)
limits are automatically set to a percentage above and below the target
rate. Select High and Low input boxes to manually adjust warning limits.
IMPORTANT: Variable Rate Drive is inoperative until at least
one target rate has been defined AND turned ON.
-
NOTE: Rate 6 is used for map based prescription. To enable controller
to use a prescription, select the "On" drop-down box under rate 6
and from RUN screen select the Rx rate. Once selected, run page has
a small Rx indicator near the Target Seeds per Area icon.
To see a rate on the RUN page as a choice, select On – Off drop down box and choose ON.
-
Select Enter button.
-
Average Spacing shown on the bottom of the screen is the CALCULATED
distance between plants based on the row width and target population
entered in monitor
-
Use One Rate for All Motors
-
Select check box to enable all motors to use one rate.
-
Leave check box empty when different rates are used for each
motor.
-
Select Disk Type drop down box.
-
If planter is configured for mechanical meters, plateless meter selections appear. Select the plateless meter installed
on machine.
NOTE: If custom plateless is selected, select Seeds per Rev. input box and enter value.
-
If planter is configured for vacuum, types of vacuum disks appear. Select the type of disk installed
in meters.
NOTE: If custom vacuumis selected,
select Holes Per Disk input box and enter
value.
-
Select Seed Disk drop down box and
select the vacuum disk used.
-
Select Population Adjust input box
and enter value.
-
NOTE: Number of rows planting check boxes are only visible if
monitor is configured for a split row or twin row machines. (See CONFIGURE
FRAME LAYOUT, ROW LAYOUT, AND DRIVE DISCONNECT WARNING in SETUP Initial
System Configuration section.)
NOTE: To ensure all settings update; actively select the rows
planting check box even if a check mark is already in the box.
Select Rows Planting check box for
appropriate rows planting configuration.
-
NOTE: High and Low Range check boxes are only visible if monitor
is configured for twin row machines. (See CONFIGURE FRAME LAYOUT,
ROW LAYOUT, AND DRIVE DISCONNECT WARNING in SETUP Initial System Configuration
section.)
Select Drive Range check box for high
or low configuration.