Liquid Fertilizer Sensor Calibration
-
NOTE: This option is only visible if machine is configured for
one or more sensors.

A59325-UN-19FEB07
Menu

A59551-UN-08MAR07
Planter Button

A59172-UN-29JAN07
Configuration Softkey

A59369-UN-20FEB07
Zero Sensor Button
Select Menu >> Planter button >> Configuration softkey
>> Sensor tab.
-
Select Fertilizer from drop down box.
-
Select each sensor, one at a time, from the Sensor drop down box.
-
Select Cal Value input box and enter
the pressure per volt from the fertilizer sensor. John Deere planters
with factory equipped sensors have a calibration value of 37.50 (English
units) or 258.55 (Metric units).
-
NOTE: Some pressure remains trapped in the system even after
it is shut down, unless manually relieved.
NOTE: Current pressure is displayed on bottom left of screen.
Relieve fertilizer pressure from system and select the Zero Sensor button.
Screen Area Information
Planter Configuration - Planter Configuration
Sensor - Sensor
Fertilizer - Fertilizer
High Pressure - High Pressure
Cal Value - Calibration Value
Pressure - Pressure
Relieve Pressure - Relieve Pressure
Select - Select
|
John Deere
is a trademark of Deere & Company
|