Select Menu >> Planter button >> Configuration softkey
>> Sensor tab.
-
Select PDF Air Pressure from drop-down
box.
-
NOTE: Step value option is only displayed in the Pneumatic Down
Force—Air Pressure Sensor setup screen for Non-XP (Enhanced
Monitoring) equipped machines.
Select Step Value, enter a value for
the pneumatic down force system to increase or decrease when adjustment
arrows (on run screen) are used for adjustment.
-
NOTE: PDF low alarm option is only displayed in the Pneumatic
Down Force—Air Pressure Sensor setup screen for Non-XP (Enhanced
Monitoring) equipped machines.
Select PDF Low Alarm to set the pressure
to determine margin. the default setting from the factory is (40 lb.)
-
Select Cal Value input box and enter
the calibration value of 494.00.
-
NOTE: Current down force is displayed on bottom left of screen.
Relieve air pressure before selecting the Zero Sensor button.