Pressurize Pneumatic Down Force System

A68216-UN-22JUL10
Properly Rolled Air Spring

A66834-UN-25MAR10
Properly Rolled Air Spring (Twin Row Planters)

A68217-UN-22JUL10
Improperly Rolled Air Spring

A66835-UN-25MAR10
Improperly Rolled Air Spring (Twin Row Planters)
-
To fill the planters down force air springs for the first time
after removing from storage:
-
In Auto mode, system begins filling the air springs to achieve
the target margin when lowered to planting position.
-
In Set-Point mode, system begins filling the air springs to
achieve the target down force when lowered to planting position.
-
Pressurize system to a minimum of 16 kg (35 lb.) of down force
displayed on monitor or approximately 83 kPa (0.8 bar) (12 psi) on
gauge.
-
Minimum down force during operation is 16 kg (35 lb.) displayed
on monitor or approximately 103 kPa (1.0 bar) (15 psi) on gauge. Failure
to maintain this pressure can result in damage to air springs.
|
|
OUO6064,0000612-19-20111110
|
|