Variable Rate Fertilizer Warnings
WARNING: Over Application!
NOTE: This warning will be followed by a “Over Application!
Pump #1 at min. setting.” caution on line “G”.

A65061-UN-30JUL09
This warning is issued if the pump adjusts to its lowest
setting and is still overapplying. The large sprocket should be installed
to change the pump speed range or a higher rate should be selected.
There is a caution associated with this warning. When the warning
is cleared there is a caution issued.
Screen Area Information
Over Application! Pump #1 is at the minimum setting. - Over Application! Pump Number 1 is at the minimum setting.
Pump is turning too FAST to achieve the desired rate. Change
the sprocket to a larger sprocket on the pump or select a higher rate. -
Pump is turning too FAST to achieve the desired rate. Change
the sprocket to a larger sprocket on the pump or select a higher rate.
Cancel Warning - Cancel Warning
WARNING: Under Application!
NOTE: This warning will be followed by a “Under Application!
Pump #1 at max. setting.” caution on line “G”.

A65062-UN-30JUL09
This warning is issued if the pump adjusts to its highest
setting and is still underapplying. The small sprocket should be installed
to change the pump speed range or a lower rate should be selected.
There is a caution associated with this warning. When the warning
is cleared there is a caution issued.
Screen Area Information
Under Application! Pump #1 is at the maximum setting. - Under Application! Pump Number 1 is at the maximum setting.
Pump is turning too SLOW to achieve the desired rate. Change
sprocket to a smaller sprocket on the pump or select a lower rate. -
Pump is turning too SLOW to achieve the desired rate. Change
sprocket to a smaller sprocket on the pump or select a lower rate.
Cancel Warning - Cancel Warning
WARNING: Pump Position Sensor Not Detected
NOTE: This warning will be followed by a “Pump Sensor
Fail.” caution on line “G”.

A65063-UN-30JUL09
This warning is issued if no signal is received from the
pump position sensor. There is a caution associated with this warning.
When the warning is cleared there is a caution issued.
Screen Area Information
Pump 1 Position Sensor Not Detected - Pump 1 Position
Sensor Not Detected
Check that the Position Sensor is plugged in. Check all harnesses
connecting to the position sensor. - Check that the Position
Sensor is plugged in. Check all harnesses connecting to the position
sensor.
Cancel Warning - Cancel Warning
WARNING: No Pump Response To Control Command
NOTE: This warning will be followed by a “Pump not responding.
Check System.” caution on line “G”.

A65064-UN-30JUL09
This warning is issued if no signal is received from the
pump adjustment motor. There is a caution associated with this warning.
When the warning is cleared there is a caution issued.
Screen Area Information
Pump 1 No Response to Control Command - Pump 1 No Response
to Control Command
Check electrical connection to the pump adjust motor. Check
mechanical connection motor to pump and pump to sensor. - Check electrical connection to the pump adjust motor. Check mechanical
connection motor to pump and pump to sensor.
Cancel Warning - Cancel Warning
WARNING: V.R. Fert System Problem. Calculated rates
may not be accurate.
NOTE: This warning will be followed by a “Pump #1 Calculated
Rate more than 10% off Target.” caution on line “G”.

A65065-UN-30JUL09
This warning is issued if calculated rate is more than 10
percent off target rate. There is a caution associated with this warning.
When the warning is cleared there is a caution issued.
Screen Area Information
V.R. Fert System Problem detected Pump #1 Calculated Rates may
not be accurate. - Variable Rate Fertilizer System Problem
detected Pump Number 1. Calculated Rates may not be accurate.
Check Tractor Radar Check Pump RPM Sensor electrical connections
and position. - Check Tractor Radar Check Pump RPM Sensor
electrical connections and position.
Cancel Warning - Cancel Warning
WARNING: V.R. Fert. System sprocket change detected.
NOTE: This warning will be followed by a “Pump #1 sprocket
change detected” caution on line “G”.

A65066-UN-30JUL09
This warning is issued if the pump application changes without
a sensor detecting motor adjustment. There is a caution associated
with this warning. When the warning is cleared there is a caution
issued.
Screen Area Information
V.R.Fert System sprocket change detected. Pump #1 recalibrated. -
Variable Rate Fertilizer System sprocket change detected. Pump
Number 1 recalibrated.
If sprockets were not changed, check Pump RPM sensor and Radar
electrical connections and position, sprockets and pump drive mechanics. -
If sprockets were not changed, check Pump RPM sensor and Radar
electrical connections and position, sprockets and pump drive mechanics.
Cancel Warning - Cancel Warning
CAUTION: V.R. Fertilizer High/Low Voltage

A65067-UN-30JUL09

A65068-UN-30JUL09
This caution is issued if variable rate fertilizer voltage
is too high or too low.
|
Screen Area Information
|
|
RUN
|
|
Page 1
|
|
|
Scan [ROW] Minimum/Maximum
|
A
|
|
0 (seed per acre) Row
|
B
|
|
0 Average Population (seed per acre)
|
C
|
|
Seed Rate 1 (seed per acre) 200000
|
D
|
|
20.0 Rate B (gallons per acre)
|
E
|
|
5.0 Speed (miles per hour)
|
F
|
|
Variable Rate Fertilizer Voltage is High
|
G
|
|
Screen Area Information
|
|
RUN
|
|
Page 1
|
|
|
Scan [ROW] Minimum/Maximum
|
A
|
|
0 (seed per acre) Row
|
B
|
|
0 Average Population (seed per acre)
|
C
|
|
Seed Rate 1 (seed per acre) 200000
|
D
|
|
20.0 Rate B (gallons per acre)
|
E
|
|
5.0 Speed (miles per hour)
|
F
|
|
Variable Rate Fertilizer Voltage is Low
|
G
|
|
|
OUO6074,000068C-19-20090730
|
|