Liquid Fertilizer Sensor Diagnostics
-
Turn tractor OFF. Turn key to accessory position.
-
Ensure that sensor wiring is properly connected.
If only one sensor is used, it MUST be connected to wire labeled
LEFT FERT.
-
Ensure that correct number of sensors are selected.
Select Planter button >> Planter Configuration softkey >> Sensors tab >> Fertilizer drop down
>> Sensors drop down. Enter number of sensors
on machine.
-
Ensure that sensors are calibrated and zeroed correctly.
-
Enter sensor calibration number of 37.5 for each sensor in calibration
input box.
-
Release trapped pressure in fertilizer manifold, then press
ZERO button for each sensor.
-
Ensure that voltages are correct.
Select Planter button >> Diagnostics softkey >> Readings tab >> System Voltages drop down.
-
Controller voltage MUST be 11 V or higher.
-
Sensor supply value is 8.0 V.
-
If voltage is ZERO, check wiring.
|
|