Start tractor.
-
Select primary Menu button >> Air Cart button >> Main softkey.
-
Start fan.
-
Drive forward and lower openers into soil at same time.
-
IMPORTANT: To prevent meter drive overload, always activate
fan before meter engagement. Meter drives are protected by a hydraulic
pressure limiter. If meter overloads with product when fan is inactive,
meter drive is disengaged.
Do not ignore “Low Fan
Speed Detected” warning. Stop tractor and verify that fan is
operational before meter engagement.
Activate meters and seed or fertilize a short distance.
-
IMPORTANT: Avoid fan motor damage. Always move SCV lever to
“Float” position to shut off fan. Never place SCV lever
into “Neutral” to shut off fan.
Leave openers in the ground and turn off meters. Allow hoses
to empty and turn off fan. Stop and shut off tractor.
-
CAUTION: To prevent serious injury or death from unexpected
machine movement, always shift the transmission to “Park”
and set the brakes before leaving the tractor.
Check product depth behind several openers on each frame section.
-
Adjust depth control to maintain chosen depth. Refer to seeding
equipment operator's manual for procedure.