Inspect and Service SectionCommand™ System
Clear Warning from Monitor
-
Stop tractor.
-
Document warning information.
-
Acknowledge warning with button on screen.
-
From the Air Cart Main screen, select
the Main softkey to open the SectionCommand run
screen.
-
Select button that corresponds to the gate twice to close and
open the gate.
-
Wait over 4 seconds for condition to clear.
-
Toggle the same gate by selecting button again.
-
Wait 1 second for warning to appear.
-
Does warning occur again?
-
Yes: Go to (Inspect
Meter Gates).
-
No: Continue seeding.
Inspect Meter Gates
-
Turn off tractor engine.
-
Close half-width disconnect handles.
-
Unplug gate detection sensor from harness.
-
Gently attempt to remove cartridge to inspect gates.
-
Can cartridge be removed?
-
Yes: Continue with procedure.
-
No: Go to (Clear
Hydraulic Contamination).
-
While on a flat surface turn over cartridge.
-
Inspect bottom of cartridge for debris.
-
Manually push gates closed and release.
-
Visually inspect the product channels in the meter housing for
blockage.
-
Is there debris in the meter keeping the gates from closing
freely?
-
Yes: Clean meter cartridge and continue
seeding.
-
No: Go to (Test
Actuators Extend).
Clear Hydraulic Contamination
-
Visually inspect the actuators to verify actuator function.
-
From the Air Cart Main screen, select
the Main softkey to open the SectionCommand™
run screen.
-
Cycle gates on and off repeatedly by pressing the individual
section button.
-
Does warning occur again?
-
Yes: See your local John Deere Dealer.
-
No: Continue seeding.
Test Actuators Extend
-
With the meter cartridge out, return to the tractor cab.
-
From the Air Cart Main screen press
the Main softkey to enter the SectionCommand™
run screen.
-
Press the individual section buttons to engage all of the actuators
and return to the cart.
-
Did all of the actuators extend properly?
-
Yes: Go to (Test
Actuators Retract).
-
No: See your local John Deere Dealer.
Test Actuators Retract
-
With the meter cartridge out, return to the tractor cab.
-
From the Air Cart Main screen press
the Main softkey to enter the SectionCommand™
run screen.
-
Press the individual section buttons to disengage all of the
actuators and return to the cart.
-
Did all of the actuators retract properly?
-
Yes: Go to (Electrical
Test).
-
No: See your local John Deere Dealer.
Electrical Test
-
Reinstall meter cartridge and plug in gate detection sensor.
-
From the Air Cart Main screen press
the Main softkey to enter the SectionCommand™
run screen.
-
Press the individual section buttons to engage all of the actuators.
-
Wait 4 seconds and press the individual section buttons again
to disengage all of the actuators.
-
Does warning occur again?
-
Yes: Go to (Test
Gate Detection Sensor).
-
No: Continue seeding.
Test Gate Detection Sensor
-
Remove failed meter cartridge, and swap with a known good cartridge.
-
Did errors continue with new cartridge?
-
Yes: Possible Gate Detection Sensor
failure, see your local John Deere Dealer.
-
No: See your local John Deere Dealer
for further troubleshooting.
|
SectionCommand
is a trademark of Deere & Company
|
MH69740,00004B7-19-20140627
|
|