Calling up Addresses and Diagnostic Trouble Codes
Procedure for dealing with diagnostic trouble codes
Every control unit monitors certain electrical circuits within the network of circuits for which it is responsible. The unit then stores the relevant diagnostic trouble code if there is a malfunction (error) or if the operator makes a mistake. However, not all of the diagnostic trouble codes indicate a problem occurring at this very moment, since most of the circuits are monitored only at the actual moment of activation or when they are actually activated (switched on). To make sure that the diagnostic trouble code you are troubleshooting is "active", you should proceed as follows:
-
Call up diagnostic trouble codes.
-
Note and clear the diagnostic trouble code(s).
-
Activate the circuit affected (functional check).
-
Call up the diagnostic trouble codes again and process them.
If it is not possible to (re-)produce a relevant diagnostic trouble code by means of a functional check and the problem is still present in the circuit, deal with the codes you noted earlier.
|
|
|
OU12401,00009B3 -19-01JAN02-1/1
|
Calling up the diagnostic trouble codes of all the control units (ALL mode)
1 Calling up the ALL mode
|
Before entering program mode, see "General Operating Instructions and Entering Program Mode".
Digital display:
Move the turn signal lever up or down (to positions for left or right turn signals).
Performance monitor:
Press the "2" button or the "0" button.
Display:
- - - : ALL
|
OK:
Enter the ALL mode. GO TO: 2.
NOT OK:
See your dealer.
|
2 Entering the ALL mode
|
Digital display:
Turning the hazard flasher switch on/off.
Performance monitor:
Press the "set/save" key.
Display:
000 : ALL
|
OK:
Check the individual control units. GO TO: 3.
OK:
Leave the ALL mode. GO TO: 7.
OK:
GO TO: Aborting or completing the program mode.
|
3 Checking the individual control units
|
Digital display:
Move the turn signal lever up or down (to positions for left or right turn signals).
Performance monitor:
Press the "2" button or the "0" button.
Display:
The first control unit appears on the display.
e.g.
BCU : nonE
oder
z.B.:
BCU : CodE
|
OK:
If display shows: nonE, GO TO: 4.
OK:
If display shows: CodE, GO TO: 5.
|
4 No diagnostic trouble codes are stored (nonE)
|
Digital display:
Move the turn signal lever up or down (to positions for left or right turn signals).
The next control unit appears on the display.
Performance monitor:
Press the "2" button or the "0" button.
The next control unit appears on the display.
|
OK:
Check the next control unit. GO TO: 3.
OK:
Leave the ALL mode. GO TO: 7.
OK:
GO TO: Calling up and confirming a control unit.
OK:
GO TO: Aborting or completing the program mode.
|
5 Diagnostic trouble codes are stored (CodE)
|
Digital display:
Turning the hazard flasher switch on/off.
Performance monitor:
Press the "set/save" key.
Display:
The first diagnostic trouble code appears on the display. For an explanation of the diagnostic service codes, see "Diagnostic Trouble Codes on Basic Control Unit / Hitch Control Unit (BCU)" and the text thereafter.
Digital display:
Move the turn signal lever up.
Performance monitor:
Press the "2" button.
Display:
The next diagnostic trouble code appears on the display.
Repeat this procedure until the display reads :
CLr?
|
OK:
Clear the diagnostic trouble codes. GO TO: 6.
OK:
GO TO: Aborting or completing the program mode.
|
6 Clearing the diagnostic trouble codes
|
Digital display:
When "CLr?" appears on the display, switch the hazard flasher switch on/off.
Performance monitor:
When "CLr?" appears on the display, press the "set/save" button.
Display:
donE
|
OK:
Check the next control unit. GO TO: 3.
OK:
Leave the ALL mode. GO TO: 7.
OK:
GO TO: Calling up and confirming a control unit.
OK:
GO TO: Aborting or completing the program mode.
|
7 Leaving the ALL mode
|
Digital display:
Pull the turn signal lever (headlight flasher) towards the steering wheel for at least 2 seconds.
Performance monitor:
Press the "Clear" button.
Display:
- - - : ALL
|
OK:
GO TO: Calling up and confirming a control unit.
OK:
GO TO: Aborting or completing the program mode.
|
Calling up and confirming a control unit
1 Calling up a control unit
|
Before entering program mode, see "General Operating Instructions and Entering Program Mode".
Digital display:
Repeatedly move the turn signal lever upward (right turn signal position) until the desired control unit is displayed.
Performance monitor:
Keep pressing the "2" key until the desired control unit appears on the display.
Display:
The control units appear on the display:
e.g.:
- - - : BCU
NOTE:
The "01" after the dot that appears in the performance monitor's display indicates how many times the control unit is located on the BUS lines.
Abbreviations used in display
Display |
Meaning |
|
BCU |
(Basic Control Unit / Hitch Control Unit) |
Basic control and hitch control unit |
BIF |
(Basic Informator) |
Basic informator |
ECU or U00 |
(Engine Control Unit) |
Engine control unit |
EPC |
(Electronic PowrQuad Controller) |
Electronic control unit for PowrQuad Plus and AutoQuad transmissions |
JDL |
(JDLink control unit) |
JDLink control unit |
PLC |
(Park Lock Controller) |
Park lock controller |
PrF |
(Performance Monitor) |
Performance monitor |
SFA |
(Suspended Front Axle & cab control unit) |
Control unit for front axle and cab suspension |
SIC |
(E-SCV / E-ICV Controller) |
Control unit for electrically activated SCVs and/or electrically activated independent control valves |
TCU |
(Tranmission Control Unit) |
Control unit for AutoPowr/IVT transmission |
TEC |
(Tractor Equipment interface Controller) |
Control unit for tractor equipment interface |
UIC |
(User Interface Controller) |
User interface controller |
|
|
|
DIA |
(Diagnosis) |
Diagnostics |
InP |
(Input) |
Input |
CAL |
(Calibration) |
Calibration |
EOC |
(End of Calibration) |
End of calibration |
End |
(End) |
End of a sequence of numbers |
Err |
(Error) |
Error |
|
OK:
Confirm the control unit. GO TO: 2.
NOT OK:
See your dealer.
|
2 Confirming the control unit
|
Digital display:
Turn the hazard flasher switch on/off.
Performance monitor:
Press the "set/save" key.
Display:
e.g.
000 : BCU.01
|
OK:
Change the control unit. GO TO: 3.
OK:
GO TO: Calling up diagnostic trouble codes of the individual control units.
OK:
GO TO: Calling up addresses
OK:
GO TO: Aborting or completing the program mode.
|
3 Changing the control unit
|
Digital display:
Pull the turn signal lever (headlight flasher) towards the steering wheel for at least 2 seconds.
Performance monitor:
Press the "Clear" button.
Display:
e.g.
- - - : BCU
|
OK:
Call up the diagnostic trouble codes. GO TO: 1.
|
Calling up diagnostic trouble codes of the individual control units
1 Calling up the diagnostic trouble codes
|
Before entering program mode, see "General Operating Instructions and Entering Program Mode".
Digital display:
Move the turn signal lever up (right turn signal position).
Performance monitor:
Press "2" button.
Display:
The display shows whether or not the selected control unit has saved any diagnostic trouble codes.
e.g.
BCU : nonE
or
e.g.
BCU : CodE
|
OK:
If display shows: nonE, GO TO: 2.
OK:
If display shows: CodE, GO TO: 3.
|
2 No diagnostic trouble codes are stored (nonE)
|
Digital display:
Move the turn signal lever up (right turn signal position).
Performance monitor:
Press "2" button.
|
OK:
GO TO: Calling up addresses
OK:
GO TO: Aborting or completing the program mode.
|
3 Diagnostic trouble codes are stored (CodE)
|
Digital display:
Turn the hazard flasher switch on/off.
Performance monitor:
Press the "set/save" key.
Display:
The first diagnostic trouble code appears on the display. For an explanation of the diagnostic service codes, see "Diagnostic Trouble Codes on Basic Control Unit / Hitch Control Unit (BCU)" and the text thereafter.
Digital display:
Move the turn signal lever up.
Performance monitor:
Press "2" button.
Display:
The next diagnostic trouble code appears on the display.
Repeat this procedure until the display reads :
CLr?
|
OK:
Clear the diagnostic trouble codes. GO TO: 4.
OK:
GO TO: Aborting or completing the program mode.
|
4 Clearing the diagnostic trouble codes
|
Digital display:
When "CLr?" appears on the display, switch the hazard flasher switch on/off.
Performance monitor:
When "CLr?" appears on the display, press the "set/save" button.
Display:
donE
|
OK:
GO TO: Calling up addresses
OK:
GO TO: Aborting or completing the program mode.
|
Calling up addresses
1 Selecting the desired address
|
Select the desired address.
There are different types of addresses.
-
Display addresses: These only show information.
-
Input addresses: These are used to configure the control unit for the appropriate tractor model and installed accessories. If the address is an input one, "InP" appears in the display.
|
OK:
If it is a display address, GO TO: 2.
OK:
If it is an input address (InP), GO TO: 3.
|
2 Calling up display addresses
|
Before entering program mode, see "General Operating Instructions and Entering Program Mode".
Digital display:
Move the turn signal lever up or down (to positions for left or right turn signals) until the desired address appears.
Performance monitor:
Press the "2" button or the "0" button until the desired address appears.
Display:
The address appears in the display.
|
OK:
GO TO: Aborting or completing the program mode.
OK:
GO TO: Calling up addresses
|
3 Calling up input addresses (InP)
|
Before entering program mode, see "General Operating Instructions and Entering Program Mode".
Digital display:
Move the turn signal lever up or down (to positions for left or right turn signals) until the desired input address appears.
Performance monitor:
Press the "2" button or the "0" button until the desired input address appears.
Display:
The input address appears in the display.
InP
also appears.
|
OK:
Access an input address (InP). GO TO: 4.
|
4 Accessing an input address (InP)
|
Digital display:
Turn the hazard flasher switch on/off.
Performance monitor:
Press the "set/save" key.
Display:
All the display positions in the input address start to flash.
|
OK:
Select information (data in figures). GO TO: 5.
|
5 Selecting information (data in figures)
|
Digital display:
Move the turn signal lever up or down (to positions for left or right turn signals) until the desired numerical data appears.
Pull the turn signal lever (headlight flasher) briefly towards the steering wheel.
The next display position starts to flash.
Keep repeating this procedure until all the display positions are showing the correct figures.
To save this information, turn the hazard flasher switch on/off.
Performance monitor:
Key in the numerical data directly at the numbered keys.
After every input, the display automatically jumps to the next display position. All the display positions in the input address flash during input.
To save this information, press the "set/save" key.
Display:
The display positions on the display stop flashing.
|
OK:
GO TO: Aborting or completing the program mode.
OK:
GO TO: Calling up addresses
|
Aborting or completing the program mode
Aborting the program mode
|
NOTE:
Diagnostics or input can be aborted at any time. However, if any data have been changed but not stored prior to ending input, these changes are lost.
Digital display:
Pull the turn signal lever (headlight flasher) towards the steering wheel for at least 2 seconds.
Performance monitor:
Press the "Clear" button.
|
OK:
This input procedure is aborted. The original data still apply.
|
Completing the program mode
|
NOTE:
Diagnosis or input is completed when a procedure has come to an end and the data has been stored in the memory.
Digital display:
Keep pulling the turn signal lever (headlight flasher) towards the steering wheel until the display shows the normal operating mode.
Performance monitor:
Press the "Clear" button.
or
Turn the main (key) switch off.
|
OK: