Multi-Function Lever (Electrical)
Multi-function lever (A) permits two SCVs to be operated at the same time. By means of rocker switch (C) an additional selective control valve can be operated (3rd function).
Switch (B) locks the lever.
Keys (E) and (F) enable other functions to be carried out.
Interlock switch actuator (D) prevents accidental actuation of the multi-function lever. The lever can operate only when the actuator is open (the operator's hand must hold it open). If the lever is held in neutral position for longer than 10 minutes, the hydraulic functions are locked out. To overcome this lock-out, take your hand out of the actuator for a moment. In case of malfunctions (e.g. part of system not working or operating error) the system can also be reactivated completely or partly by carrying out the procedure described above.
Pulling lever (A) back makes the front loader rise. Pushing the lever forward until perceptible resistance is reached makes the front loader go down. If the lever is pushed forward beyond the resistance, it engages in a detent and the front loader is in its float position.
Moving the lever to the left makes the loader bucket tip up. Moving the lever to the left makes the loader bucket is dumped.
If the lever is moved to the right beyond the resistance twice in quick succession and held there, the loader bucket will vibrate.
|
A -Multi-function lever
B-Transport lock switch
C-Rocker switch, 3rd function
D-Interlock switch actuator
E-Switch, 4th function
F-Switch, 5th function
|