Power Outlet Sockets

Signal socket and 3-terminal power outlet socket

7-terminal signal socket (A) is protected by a 30-amp fuse.

Terminal Wire color Description
1 Red Speed determined by radar
2 Brown Speed of wheels
3 Orange Rear PTO speed
4 - -
5 - -
6 Blue Power supply
7 Black Ground

 

Terminals 15/80 and 82 of 3-terminal power outlet socket (B) are protected by a 30-amp fuse. Terminal 31 is ground.

3-terminal power outlet socket (B) and signal socket (A) are used to connect electrical equipment. Turn key in main switch clockwise or counterclockwise to provide power to the 3-terminal power outlet socket (B) and signal socket (A).

NOTE: A conversion kit is available from your John Deere dealer for equipment that requires a constant power supply even when the ignition is off.

 

LX1027085
LX009168

OU12401,00101DF -19-01JAN02-1/2


Routing the cables

The rear window of the cab is provided with two openings, allowing the cables to be routed. Open the window and take out the rubber stoppers. Cut the rubber stoppers at the incisions provided to enable the cables to be routed. Connect the plugs, insert the rubber stoppers and close the window.

LX1026097

OU12401,00101DF -19-01JAN02-2/2