Rate of Cylinder Operation
The lowering and raising speed can be adjusted at load control valves (A).
IMPORTANT:
Full extension and retraction of a remote cylinder should require at least 1.5 to 2 seconds. Faster speeds may cause damage.
NOTE:
On 200 Series control valves adjustment is not possible while oil is flowing.
|