Power Outlet Sockets

7-terminal signal socket (A) is protected by a 30-amp fuse.

Terminal Wire color Description
1
2
3
4
5
6
7
Red
Brown
Orange
-
-
Blue
Black
Speed determined by radar
Speed of wheels
Rear PTO speed
-
-
Power supply
Ground

 

Terminals 15/80 and 82 of 3-terminal power outlet socket (B) are protected by a 30-amp fuse. Terminal 31 is ground.

3-terminal power outlet socket (B) and signal socket (A) are used to connect electrical equipment. Turn key in main switch clockwise or counterclockwise to provide power to the 3-terminal power outlet socket (B) and signal socket (A).

NOTE: A conversion kit is available from your John Deere dealer for equipment that requires a constant power supply even when the ignition is off.