Light |
Diagnostic Trouble Codes |
Description |
blue |
SIC 000629.12 |
Controller internal fault |
blue |
SIC 000639.12 |
Controller internal fault |
blue |
SIC 000639.13 |
29-BIT CAN BUS, high error rate |
blue |
SIC 000639.19 |
29-BIT CAN BUS, very high error rate |
blue |
SIC 334001.09 |
ECU or BCU is/are not sending any data (engine speed) |
blue |
SIC 334002.09 |
BCU is not transmitting any data (engine operating hours) |
blue |
SIC 334003.09 |
Transmission control unit or BIF is/are not sending any data (hydraulic oil temperature) |
blue |
SIC 334010.01 |
Hydraulic oil temperature too low |
blue |
SIC 334028.14 |
Controller not calibrated |
blue |
SIC 334051.14 |
E-ICV no.1, potentiometer or switch at multifunction lever is faulty |
blue |
SIC 334052.14 |
E-ICV no.2, potentiometer or switch at multifunction lever is faulty |
blue |
SIC 334053.14 |
E-ICV no.3, potentiometer or switch at multifunction lever is faulty |
blue |
SIC 334059.31 |
5-volt power supply is faulty |
blue |
SIC 334060.14 |
E-ICV, transport lock switch is faulty |
blue |
SIC 334061.14 |
E-ICV, safety switch is faulty |
blue |
SIC 334106.12 |
Controller internal fault |
blue |
SIC 334136.18 |
E-ICV no.1-stepper motor, supply voltage too low |
blue |
SIC 334137.01 |
E-ICV no.1-stepper motor, supply voltage very low |
blue |
SIC 334138.00 |
E-ICV no.1-stepper motor, supply voltage too high |
blue |
SIC 334139.14 |
E-ICV no.1-stepper motor, no connection to controller |
blue |
SIC 334140.14 |
E-ICV no.1-stepper motor, coil temperature too low |
blue |
SIC 334141.14 |
E-ICV no.1-stepper motor, coil temperature too high |
blue |
SIC 334144.18 |
E-ICV no.2-stepper motor, supply voltage too low |
blue |
SIC 334145.01 |
E-ICV no.2-stepper motor, supply voltage very low |
blue |
SIC 334146.00 |
E-ICV no.2-stepper motor, supply voltage too high |
blue |
SIC 334147.14 |
E-ICV no.2-stepper motor, no connection to controller |
blue |
SIC 334148.14 |
E-ICV no.2-stepper motor, coil temperature too low |
blue |
SIC 334149.14 |
E-ICV no.2-stepper motor, coil temperature too high |
blue |
SIC 334152.18 |
E-ICV no.3-stepper motor, supply voltage too low |
blue |
SIC 334153.01 |
E-ICV no.3-stepper motor, supply voltage very low |
blue |
SIC 334154.00 |
E-ICV no.3-stepper motor, supply voltage too high |
blue |
SIC 334155.14 |
E-ICV no.3-stepper motor, no connection to controller |
blue |
SIC 334156.14 |
E-ICV no.3-stepper motor, coil temperature too low |
blue |
SIC 334157.14 |
E-ICV no.3-stepper motor, coil temperature too high |
blue |
SIC 334201.14 |
E-ICV no.1, stepper motor does not start |
blue |
SIC 334202.14 |
E-ICV no.2, stepper motor does not start |
blue |
SIC 334203.14 |
E-ICV no.3, stepper motor does not start |
blue |
SIC 334221.14 |
E-ICV no.1, stepper motor does not respond to command from controller |
blue |
SIC 334222.14 |
E-ICV no.2, stepper motor does not respond to command from controller |
blue |
SIC 334223.14 |
E-ICV no.3, stepper motor does not respond to command from controller |
blue |
SIC 334240.14 |
Controller is connected to the wrong harness connector |