Diagnostic Trouble Codes on E-ICV Controller (SIC)

Light Diagnostic Trouble Codes Description
blue SIC 000629.12 Controller internal fault
blue SIC 000639.12 Controller internal fault
blue SIC 000639.13 29-BIT CAN BUS, high error rate
blue SIC 000639.19 29-BIT CAN BUS, very high error rate
blue SIC 334001.09 ECU or BCU is/are not sending any data (engine speed)
blue SIC 334002.09 BCU is not transmitting any data (engine operating hours)
blue SIC 334003.09 Transmission control unit or BIF is/are not sending any data (hydraulic oil temperature)
blue SIC 334010.01 Hydraulic oil temperature too low
blue SIC 334028.14 Controller not calibrated
blue SIC 334051.14 E-ICV no.1, potentiometer or switch at multifunction lever is faulty
blue SIC 334052.14 E-ICV no.2, potentiometer or switch at multifunction lever is faulty
blue SIC 334053.14 E-ICV no.3, potentiometer or switch at multifunction lever is faulty
blue SIC 334059.31 5-volt power supply is faulty
blue SIC 334060.14 E-ICV, transport lock switch is faulty
blue SIC 334061.14 E-ICV, safety switch is faulty
blue SIC 334106.12 Controller internal fault
blue SIC 334136.18 E-ICV no.1-stepper motor, supply voltage too low
blue SIC 334137.01 E-ICV no.1-stepper motor, supply voltage very low
blue SIC 334138.00 E-ICV no.1-stepper motor, supply voltage too high
blue SIC 334139.14 E-ICV no.1-stepper motor, no connection to controller
blue SIC 334140.14 E-ICV no.1-stepper motor, coil temperature too low
blue SIC 334141.14 E-ICV no.1-stepper motor, coil temperature too high
blue SIC 334144.18 E-ICV no.2-stepper motor, supply voltage too low
blue SIC 334145.01 E-ICV no.2-stepper motor, supply voltage very low
blue SIC 334146.00 E-ICV no.2-stepper motor, supply voltage too high
blue SIC 334147.14 E-ICV no.2-stepper motor, no connection to controller
blue SIC 334148.14 E-ICV no.2-stepper motor, coil temperature too low
blue SIC 334149.14 E-ICV no.2-stepper motor, coil temperature too high
blue SIC 334152.18 E-ICV no.3-stepper motor, supply voltage too low
blue SIC 334153.01 E-ICV no.3-stepper motor, supply voltage very low
blue SIC 334154.00 E-ICV no.3-stepper motor, supply voltage too high
blue SIC 334155.14 E-ICV no.3-stepper motor, no connection to controller
blue SIC 334156.14 E-ICV no.3-stepper motor, coil temperature too low
blue SIC 334157.14 E-ICV no.3-stepper motor, coil temperature too high
blue SIC 334201.14 E-ICV no.1, stepper motor does not start
blue SIC 334202.14 E-ICV no.2, stepper motor does not start
blue SIC 334203.14 E-ICV no.3, stepper motor does not start
blue SIC 334221.14 E-ICV no.1, stepper motor does not respond to command from controller
blue SIC 334222.14 E-ICV no.2, stepper motor does not respond to command from controller
blue SIC 334223.14 E-ICV no.3, stepper motor does not respond to command from controller
blue SIC 334240.14 Controller is connected to the wrong harness connector

 

OU12401,0000B30 -19-01JUL02-1/1