Air Cleaner

If the air cleaner indicator lamp glows during operation, remove and clean the primary filter element.

The service interval may be extended briefly, e.g. until the next suitable opportunity. Provided the cleaner is serviced properly, this will not adversely affect its performance.

The primary element can be cleaned up to five times. Thereafter, or at the latest after 1500 hours of operation (or 2 years), it must be replaced.

Open the hood, turn latch (A) upward. Push cleaner housing (B) to the left and remove from the front. Pull the primary filter element out of the cleaner housing.

IMPORTANT: Never run the engine without the primary filter element!

LX1018205