Operation and Calibration
IMPLEMENT (2)
Press the
IMPLEMENT
switch to change implement indicator (C) to the "up" or "down" position.
When the implement indicator arrow points down, all measurement functions are engaged.
Implement Selector Calibration
Procedure coordinates the position of the indicator arrow (C) to the position of the hitch or implement switch.
Hold
IMPLEMENT
switch four seconds to change the function code (B).
Display will show "IP:" and a function code (3,7, or 32). This number indicates which device is in control of the implement arrow (C).
"3" hitch position sensor (raise limit setting).
"7" implement switch on touch pad.
"32" first downward movement automatically selects which external device will control the implement indicator arrow (implement switch or the hitch position sensor.). The "A" in the display (IP:A ) represents this auto-seek mode.
NOTE:
It may be necessary to press implement switch (D) to change indicator arrow (C).
If the implement switch (D) does not control the indicator arrow, "7" has not been selected as a function code.
For applications which use the hitch sensor or implement switch exclusively, use "3" or "7".
A "0" or any other number other than the above will completely shut off the "implement" function.
Press
SET
(E). Input 3,7, or 32 using touch pad, then press
SAVE
(E).
|