Adjustment of Pressure Limit at Selective Control Valves (300 Series)

NOTE: All selective control valves are factory adjusted to 18000 kPa (180 bar; 2610 psi).

If the selective control valve in lock function switches off too early (control lever goes to neutral too early), or if it switches off too late or not at all (lever moves to neutral too late or not at all), proceed as follows:

1. Disconnect hydraulic hoses at the connectors (if equipped).

2. Engage the locking function (A) and move flow control valve (B) to the mid-position.

3. Take out the plug and insert a screwdriver.

4. Start the engine and turn the screw clockwise as far as it will go.

5. Move SCV control lever to the "raise" or "lower" position (the control lever remains in the "raise" or "lower" position).

6. Turn the screw counter-clockwise until the control lever jumps into neutral.

7. Slacken off the screw by turning it half a turn counter-clockwise.

NOTE: One full turn changes the pressure by approx. 4600 kPa (46 bar; 670 psi).

8. Take out the screwdriver and re-install the plug.

LX1015086
LX1015087

LX,OEQUIP006333 -19-01JUN96-1/1